A house drain is the horizontal main drain under your basement floor.
Correct way to set pvc sewer pipe in concrete floor.
Pvc adhesive and metal pipes require pre cast metal fittings and must be bolted in place.
However in nyc the house sewer line itself must still be extra heavy cast iron pipe.
Under the floor the other end of the pipe connects to other drain pipes in the house so before i cover the area with more carpeting i d like to seal that pipe off permanently to avoid any possible leakage in the future.
Pour the mixed concrete around the pvc pipe using a large metal funnel or a spade.
Pipes passing through wall concrete.
It should be packed tight to create a solid firm foundation and to prevent cracking during temperature fluctuations.
Pvc pipes require pre cast pvc angle fittings.
Pack the concrete around the pvc pipe to prevent air gaps.
The drainpipes are made of cast iron galvanized pipe copper or plastic.
Water supply sewer line below garden area driveway.
Pack the layer directly underneath the pvc pipe.
The vent pipes remove or exhaust sewer gases and allow air to enter the system so that the wastewater flows freely.
The sewer line for the house.
Pipe risers penetrating floor or roof slab.
Because leaving old pipe in the ground causes confusion and delay for future excavating construction work in the.
Step 3 measure from the inside threads of the up turn of your fitting metal or pvc to a point that is a minimum of 8 inches above the finished height of your slab.
A sag in a sewer pipe will eventually lead to standing water and sediment collecting in the middle of the line which in turn can lead to erosion blockages and a major backup for the homeowner.
Local building codes that regulate the materials used in the dwv system have changed over the years so most older homes have a combination of materials.
When an old under ground pipe system most commonly water sanitary and storm is replaced or no longer needed due to an upgrade the project engineer may wish for the existing pipe to be removed or abandoned.
For pvc pipe crossing thru block wall.
In some areas the home sewer line itself is also pvc or a different variety of plastic tubing.
Called around to the mason and the contractor who said they see pvc in concrete often and that it should be okay pour the foundation and embed the line under the concrete.
About 6 feet of the pipe would be embedded.
Pipe sleeve thru wall.
Detail of cleanout at a high level.
Pipe sleeve in roof.
Sewer pipe is installed one section at a time typically starting at the lower end of the pipe run and working up to the higher elevation.
Modern sewer pipe is made of pvc and is joined either with gasketed fittings or with solvent glue.
Standard pipe size for residential lines is 4 inches.
Sewer line bellies are a common problem that can create aggravating sewer pipe problems for property owners.
While digging a foundation for a fire place we are adding to our existing home we ran into suprise.